| Hangar (Building 91)
|
|
Area Facilities Heating Electrical power Lighting Compressed Air Services Overhead Cranes Fire Protection
| 9520m2 4 x B737/A320 aircraft docking system HTHW projection and radiant heaters 2 x 90KVA 400Hz motor generators, 415V 3 phase, 240V single phase 400W mercury vapour and 40W fluorescent 6.5 bar (100psi) Hot and cold water 2 x 3 ton gantry cranes NFPA 409 specification
|
| Hangar (Building 145)
|
|
Area Facilities Heating Electrical power Lighting Compressed Air Services Overhead Cranes Fire Protection
| 8120m2 Hydraulic undercarriage pits, B767 aircraft docking system HTHW projection and radiant heaters 2 x 120KVA 400Hz motor generators, 415V 3 phase, 240V single phase 1000W metal halide and 40W fluorescent 6.5 bar (100psi) Hot and cold water 1 x 10 ton and 1 x 0.5 ton gantry cranes NFPA 409 specification
|
| Avionics (Hangar 91 Annex)
|
|
Area Facilities
Heating Electrical power Lighting Compressed Air Services Fire Protection
| 690m2 ESD controlled environment, high current (70A) 115V 3 phase variable power environmentally controlled air conditioning 115V 3 phase, 28VDC, 240V single phase 40W fluorescent 6.5 bar (100psi) Hot and cold water Australian Standards specification
|
| Hydraulics and Pressurisation (Hangar 91 Annex)
|
|
Area Facilities Heating Electrical power Lighting Compressed Air Services Overhead Cranes Fire Protection
| 750m2 Nitrogen gas lines, fuel room, cleaning room environmentally controlled air conditioning 115V 3 phase, 28VDC, 240V single phase 40W fluorescent 6.5 bar (100psi) Hot and cold water 2 x 1 ton gantry cranes Australian Standards specification
|
Wheels and Brakes (Hangar 91 Annex)
|
|
Area Facilities
Heating Electrical power Lighting Compressed Air Services Overhead Cranes Fire Protection
| 800m2 Trichloroethylene vapour degreaser, sanding/plastic bead blasting rooms, Nitrogen gas lines environmentally controlled air conditioning 115V 3 phase, 28VDC, 240V single phase 40W fluorescent 6.5 bar (100psi) Hot and cold water 2 x 2 ton gantry cranes Australian Standards specification
|
| Instruments and Oxygen (Hangar 91 Annex - 1st Floor)
|
|
Area Facilities
| 900m2 EHP Oxygen/Nitrogen/Carbon Dioxide lines, Class 1 and 2 clean rooms, relative temperature and humidity monitoring, ESD controlled environment, solder bath, wire winding, accredited hydrostatic test station, 6 x Dry air vacuum pumps, 3 x Oxygen compatible vacuum pumps
|
Heating Electrical power Lighting Compressed Air Services Fire Protection
| environmentally controlled air conditioning 115V 3 phase, 28VDC, 240V single phase 40W fluorescent 6.5 bar (100psi) Hot and cold water Australian Standards specification
|
| Calibration (Hangar 91 Annex - 1st Floor)
|
|
Area Facilities Heating Electrical power Lighting Compressed Air Services Fire Protection
| 130m2 Dry air and Nitrogen lines, relative temperature and humidity monitoring environmentally controlled air conditioning 115V 3 phase, 28VDC, 240V single phase 40W fluorescent 6.5 bar (100psi) Hot and cold water Australian Standards specification
|
| Non Destructive Testing (Building 138)
|
|
Area Facilities Heating Electrical power Lighting Compressed Air Services Fire Protection
| 257m2 Laboratory and large X Ray cell Low temperature hot water 415V 3 phase 400W mercury vapour and 40W fluorescent 6.5 bar (100psi) Hot and cold water Australian Standards specification
|